-- Table: public.asyncmotor_rated -- DROP DROP TABLE IF EXISTS public.asyncmotor_rated; DROP SEQUENCE IF EXISTS public.asyncmotor_rated_id_seq; -- CREATE CREATE SEQUENCE IF NOT EXISTS public.asyncmotor_rated_id_seq; CREATE TABLE IF NOT EXISTS public.asyncmotor_rated ( id integer NOT NULL DEFAULT nextval('asyncmotor_rated_id_seq'::regclass), component_id INTEGER NOT NULL DEFAULT -1, voltage DOUBLE PRECISION NOT NULL DEFAULT 0.4, -- 额定电压 0.4~35 power DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 额定功率 0.01~ eff_100fl DOUBLE PRECISION NOT NULL DEFAULT 96.8, -- 额定效率 0~100(%) eff_75fl DOUBLE PRECISION NOT NULL DEFAULT 97.5, -- 额定效率 0~100(%) eff_50fl DOUBLE PRECISION NOT NULL DEFAULT 97.5, -- 额定效率 0~100(%) eff_0fl DOUBLE PRECISION NOT NULL DEFAULT 0, -- 额定效率 0~100(%) pf_100fl DOUBLE PRECISION NOT NULL DEFAULT 88, -- 额定功率因数 0~100(%) pf_75fl DOUBLE PRECISION NOT NULL DEFAULT 85, -- 额定功率因数 0~100(%) pf_50fl DOUBLE PRECISION NOT NULL DEFAULT 80, -- 额定功率因数 0~100(%) pf_0fl DOUBLE PRECISION NOT NULL DEFAULT 70, -- 额定功率因数 0~100(%) fla DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 满载电流 0.01~ sf DOUBLE PRECISION NOT NULL DEFAULT 1, -- 电动机使用系数 0~10 nla DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 空载电流 0~999 rc DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 额定转子电流 0.01~ ocv DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 额定开路电压 0.4~35 sc_mpl DOUBLE PRECISION NOT NULL DEFAULT 6.5, -- 启动电流倍数 1~20 sc DOUBLE PRECISION NOT NULL DEFAULT 0.01~65536, -- 启动电流值 1~20 st_100un DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 起动时间 1~999 st_80un DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 起动时间 1~999 pf DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 1~100(%) xr DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 0~100 pole_num SMALLINT NOT NULL DEFAULT 4, -- 极数 1~200 sync_speed INTEGER NOT NULL DEFAULT 1500, -- 同步转速 30~3000 rated_speed INTEGER NOT NULL DEFAULT 1498, -- 额定转速 0~3000 rated_slip DOUBLE PRECISION NOT NULL DEFAULT 98.5, -- 额定转差率 0~100(%) rated_torque DOUBLE PRECISION NOT NULL DEFAULT 0.0, -- 额定转矩 0.01~ max_torque_pct DOUBLE PRECISION NOT NULL DEFAULT 200, -- 最大转矩百分比(相对额定转矩) 100~500(%) stall_torque_pct DOUBLE PRECISION NOT NULL DEFAULT 60, -- 堵转转矩百分比(相对额定转矩) 1~100(%) op integer NOT NULL DEFAULT '-1'::integer, ts timestamp with time zone NOT NULL DEFAULT CURRENT_TIMESTAMP, CONSTRAINT asyncmotor_rated_id_PrimaryKey PRIMARY KEY (id), CONSTRAINT asyncmotor_rated_ForeignKey_component_id FOREIGN KEY (component_id) REFERENCES public.component (id) MATCH SIMPLE ON UPDATE NO ACTION ON DELETE NO ACTION ) TABLESPACE pg_default; ALTER TABLE IF EXISTS public.asyncmotor_rated OWNER to postgres; COMMENT ON TABLE public.asyncmotor_rated IS '存储异步电动机的额定参数';