CREATE TABLE public."BusbarSection" ( id serial NOT NULL, global_uuid uuid NOT NULL, busbar_number integer NOT NULL, busbar_name character varying(20) default 'Busx' NOT NULL, standard_voltage decimal(5, 2) NOT NULL, busbar_desc character varying(100) NOT NULL, is_service boolean NULL default false, status character varying(10) NOT NULL, power_grid_name character varying(10) NOT NULL, region_name character varying(10) NOT NULL, factory_station_name character varying(10) NOT NULL, voltage_percent_value decimal(5, 2) default 100 NOT NULL, voltage_calculcated_value decimal(5, 2) default 35 NOT NULL, phase_angle decimal(5, 2) default 0 NOT NULL, rated_current decimal(7, 2) default 1000 NOT NULL, dynamic_stable_current decimal(7, 2) default 40 NOT NULL, min_load_adjustment_coefficient integer default 100 NOT NULL, max_load_adjustment_coefficient integer default 100 NOT NULL, busbar_type character varying(10) NOT NULL, min_s3_capacities decimal(7, 2) default 0 NOT NULL, max_s3_capacities decimal(7, 2) default 0 NOT NULL, min_s3_current decimal(7, 2) default 0 NOT NULL, max_s3_current decimal(7, 2) default 0 NOT NULL, max_z3_impedance decimal(6, 3) default 0.05 NOT NULL, min_z3_impedance decimal(6, 3) default 0.1 NOT NULL, min_s1_capacity decimal(7, 2) default 0 NOT NULL, max_s1_capacity decimal(7, 2) default 0 NOT NULL, min_s1_current decimal(7, 2) default 0 NOT NULL, max_s1_current decimal(7, 2) default 0 NOT NULL, min_z1_impedance decimal(7, 4) default 0 NOT NULL, max_z1_impedance decimal(7, 4) default 0 NOT NULL, reference_voltage decimal(5, 2) default 37 NOT NULL, reference_current decimal(7, 2) default 100 NOT NULL, under_voltage_warning_threshold integer default 95 NOT NULL, under_voltage_warning_running_time integer default 10 NOT NULL, under_voltage_alarm_threshold integer default 90 NOT NULL, under_voltage_alarm_running_time integer default 10 NOT NULL, over_voltage_warning_threshold integer default 105 NOT NULL, over_voltage_warning_running_time integer default 60 NOT NULL, over_voltage_alarm_threshold integer default 110 NOT NULL, over_voltage_alarm_running_time integer default 10 NOT NULL, p_max decimal(7, 2) default 0 NOT NULL, q_max decimal(7, 2) default 0 NOT NULL, ulim decimal(5, 2) default 90 NOT NULL, plim decimal(5, 2) default 30 NOT NULL, qlim decimal(5, 2) default 30 NOT NULL, measurement_level_current character varying(10) NOT NULL, measurement_level_voltage character varying(10) NOT NULL, protection_level_current character varying(10) NOT NULL, protection_level_voltage_t character varying(10) NOT NULL, trend character varying(10) NOT NULL, frequency character varying(10) NOT NULL, status_measurement_point character varying(10) NOT NULL, context jsonb NULL, comment character varying(4096) NULL ); ALTER TABLE public."BusbarSection" ADD CONSTRAINT "BusbarSection_pkey" PRIMARY KEY (global_uuid)