CREATE TABLE public."BusbarSection" (
|
|
id serial NOT NULL,
|
|
global_uuid uuid NOT NULL,
|
|
busbar_number integer NOT NULL,
|
|
busbar_name character varying(20) default 'Busx' NOT NULL,
|
|
standard_voltage decimal(5, 2) NOT NULL,
|
|
busbar_desc character varying(100) NOT NULL,
|
|
is_service boolean NULL default false,
|
|
status character varying(10) NOT NULL,
|
|
power_grid_name character varying(10) NOT NULL,
|
|
region_name character varying(10) NOT NULL,
|
|
factory_station_name character varying(10) NOT NULL,
|
|
voltage_percent_value decimal(5, 2) default 100 NOT NULL,
|
|
voltage_calculcated_value decimal(5, 2) default 35 NOT NULL,
|
|
phase_angle decimal(5, 2) default 0 NOT NULL,
|
|
rated_current decimal(7, 2) default 1000 NOT NULL,
|
|
dynamic_stable_current decimal(7, 2) default 40 NOT NULL,
|
|
min_load_adjustment_coefficient integer default 100 NOT NULL,
|
|
max_load_adjustment_coefficient integer default 100 NOT NULL,
|
|
busbar_type character varying(10) NOT NULL,
|
|
min_s3_capacities decimal(7, 2) default 0 NOT NULL,
|
|
max_s3_capacities decimal(7, 2) default 0 NOT NULL,
|
|
min_s3_current decimal(7, 2) default 0 NOT NULL,
|
|
max_s3_current decimal(7, 2) default 0 NOT NULL,
|
|
max_z3_impedance decimal(6, 3) default 0.05 NOT NULL,
|
|
min_z3_impedance decimal(6, 3) default 0.1 NOT NULL,
|
|
min_s1_capacity decimal(7, 2) default 0 NOT NULL,
|
|
max_s1_capacity decimal(7, 2) default 0 NOT NULL,
|
|
min_s1_current decimal(7, 2) default 0 NOT NULL,
|
|
max_s1_current decimal(7, 2) default 0 NOT NULL,
|
|
min_z1_impedance decimal(7, 4) default 0 NOT NULL,
|
|
max_z1_impedance decimal(7, 4) default 0 NOT NULL,
|
|
reference_voltage decimal(5, 2) default 37 NOT NULL,
|
|
reference_current decimal(7, 2) default 100 NOT NULL,
|
|
under_voltage_warning_threshold integer default 95 NOT NULL,
|
|
under_voltage_warning_running_time integer default 10 NOT NULL,
|
|
under_voltage_alarm_threshold integer default 90 NOT NULL,
|
|
under_voltage_alarm_running_time integer default 10 NOT NULL,
|
|
over_voltage_warning_threshold integer default 105 NOT NULL,
|
|
over_voltage_warning_running_time integer default 60 NOT NULL,
|
|
over_voltage_alarm_threshold integer default 110 NOT NULL,
|
|
over_voltage_alarm_running_time integer default 10 NOT NULL,
|
|
p_max decimal(7, 2) default 0 NOT NULL,
|
|
q_max decimal(7, 2) default 0 NOT NULL,
|
|
ulim decimal(5, 2) default 90 NOT NULL,
|
|
plim decimal(5, 2) default 30 NOT NULL,
|
|
qlim decimal(5, 2) default 30 NOT NULL,
|
|
measurement_level_current character varying(10) NOT NULL,
|
|
measurement_level_voltage character varying(10) NOT NULL,
|
|
protection_level_current character varying(10) NOT NULL,
|
|
protection_level_voltage_t character varying(10) NOT NULL,
|
|
trend character varying(10) NOT NULL,
|
|
frequency character varying(10) NOT NULL,
|
|
status_measurement_point character varying(10) NOT NULL,
|
|
context jsonb NULL,
|
|
comment character varying(4096) NULL
|
|
);
|
|
|
|
ALTER TABLE
|
|
public."BusbarSection"
|
|
ADD
|
|
CONSTRAINT "BusbarSection_pkey" PRIMARY KEY (global_uuid) |