chore(inputs.modbus): Improve deprecation documentation (#13832)
This commit is contained in:
parent
d4a00dd8d6
commit
2dd5682e1a
|
|
@ -104,7 +104,8 @@ See the [CONFIGURATION.md][CONFIGURATION.md] for more details.
|
|||
## data_type - INT8L, INT8H, UINT8L, UINT8H (low and high byte variants)
|
||||
## INT16, UINT16, INT32, UINT32, INT64, UINT64,
|
||||
## FLOAT16-IEEE, FLOAT32-IEEE, FLOAT64-IEEE (IEEE 754 binary representation)
|
||||
## FLOAT32, FIXED, UFIXED (fixed-point representation on input)
|
||||
## FIXED, UFIXED (fixed-point representation on input)
|
||||
## FLOAT32 is a deprecated alias for UFIXED for historic reasons, should be avoided
|
||||
## scale - the final numeric variable representation
|
||||
## address - variable address
|
||||
|
||||
|
|
@ -383,6 +384,9 @@ Directly jump to the styles:
|
|||
This is the original style used by this plugin. It allows a per-register
|
||||
configuration for a single slave-device.
|
||||
|
||||
> [!NOTE]
|
||||
> _For legacy reasons this configuration style is not completely consistent with the other styles. Especially `FLOAT32` which suggests a floating point representation is actually a_ ___Fixed Point___ _data type and should be considered_ ___deprecated___
|
||||
|
||||
#### Usage of `data_type`
|
||||
|
||||
The field `data_type` defines the representation of the data value on input from
|
||||
|
|
@ -414,7 +418,7 @@ modbus data source. For _coil_ and _discrete_ registers only `UINT16` is valid.
|
|||
Use these types if your modbus registers contain a value that is encoded in this
|
||||
format. These types always include the sign, therefore no variant exists.
|
||||
|
||||
##### Fixed Point: `FIXED`, `UFIXED` (`FLOAT32`)
|
||||
##### Fixed Point: `FIXED`, `UFIXED`, (`FLOAT32` - _deprecated_)
|
||||
|
||||
These types are handled as an integer type on input, but are converted to
|
||||
floating point representation for further processing (e.g. scaling). Use one of
|
||||
|
|
@ -430,7 +434,7 @@ Select the type `FIXED` when the input type is declared to hold signed integer
|
|||
values. Your documentation of the modbus device should indicate this with a term
|
||||
like 'int32 containing fixed-point representation with N decimal places'.
|
||||
|
||||
(FLOAT32 is deprecated and should not be used. UFIXED provides the same
|
||||
(`FLOAT32` is deprecated and should not be used. `UFIXED` provides the same
|
||||
conversion from unsigned values).
|
||||
|
||||
---
|
||||
|
|
|
|||
|
|
@ -5,6 +5,7 @@ import (
|
|||
"fmt"
|
||||
|
||||
"github.com/influxdata/telegraf"
|
||||
"github.com/influxdata/telegraf/models"
|
||||
)
|
||||
|
||||
//go:embed sample_register.conf
|
||||
|
|
@ -258,6 +259,14 @@ func (c *ConfigurationOriginal) validateFieldDefinitions(fieldDefs []fieldDefini
|
|||
}
|
||||
|
||||
func (c *ConfigurationOriginal) normalizeInputDatatype(dataType string, words int) (string, error) {
|
||||
if dataType == "FLOAT32" {
|
||||
models.PrintOptionValueDeprecationNotice(telegraf.Warn, "input.modbus", "data_type", "FLOAT32", telegraf.DeprecationInfo{
|
||||
Since: "v1.16.0",
|
||||
RemovalIn: "v2.0.0",
|
||||
Notice: "Use 'UFIXED' instead",
|
||||
})
|
||||
}
|
||||
|
||||
// Handle our special types
|
||||
switch dataType {
|
||||
case "FIXED":
|
||||
|
|
|
|||
|
|
@ -32,7 +32,8 @@
|
|||
## data_type - INT8L, INT8H, UINT8L, UINT8H (low and high byte variants)
|
||||
## INT16, UINT16, INT32, UINT32, INT64, UINT64,
|
||||
## FLOAT16-IEEE, FLOAT32-IEEE, FLOAT64-IEEE (IEEE 754 binary representation)
|
||||
## FLOAT32, FIXED, UFIXED (fixed-point representation on input)
|
||||
## FIXED, UFIXED (fixed-point representation on input)
|
||||
## FLOAT32 is a deprecated alias for UFIXED for historic reasons, should be avoided
|
||||
## scale - the final numeric variable representation
|
||||
## address - variable address
|
||||
|
||||
|
|
|
|||