# Retrieve data from OPCUA devices
|
|
[[inputs.opcua]]
|
|
## Metric name
|
|
# name = "opcua"
|
|
#
|
|
## OPC UA Endpoint URL
|
|
# endpoint = "opc.tcp://localhost:4840"
|
|
#
|
|
## Maximum time allowed to establish a connect to the endpoint.
|
|
# connect_timeout = "10s"
|
|
#
|
|
## Maximum time allowed for a request over the estabilished connection.
|
|
# request_timeout = "5s"
|
|
#
|
|
## Security policy, one of "None", "Basic128Rsa15", "Basic256",
|
|
## "Basic256Sha256", or "auto"
|
|
# security_policy = "auto"
|
|
#
|
|
## Security mode, one of "None", "Sign", "SignAndEncrypt", or "auto"
|
|
# security_mode = "auto"
|
|
#
|
|
## Path to cert.pem. Required when security mode or policy isn't "None".
|
|
## If cert path is not supplied, self-signed cert and key will be generated.
|
|
# certificate = "/etc/telegraf/cert.pem"
|
|
#
|
|
## Path to private key.pem. Required when security mode or policy isn't "None".
|
|
## If key path is not supplied, self-signed cert and key will be generated.
|
|
# private_key = "/etc/telegraf/key.pem"
|
|
#
|
|
## Authentication Method, one of "Certificate", "UserName", or "Anonymous". To
|
|
## authenticate using a specific ID, select 'Certificate' or 'UserName'
|
|
# auth_method = "Anonymous"
|
|
#
|
|
## Username. Required for auth_method = "UserName"
|
|
# username = ""
|
|
#
|
|
## Password. Required for auth_method = "UserName"
|
|
# password = ""
|
|
#
|
|
## Option to select the metric timestamp to use. Valid options are:
|
|
## "gather" -- uses the time of receiving the data in telegraf
|
|
## "server" -- uses the timestamp provided by the server
|
|
## "source" -- uses the timestamp provided by the source
|
|
# timestamp = "gather"
|
|
#
|
|
## Node ID configuration
|
|
## name - field name to use in the output
|
|
## namespace - OPC UA namespace of the node (integer value 0 thru 3)
|
|
## identifier_type - OPC UA ID type (s=string, i=numeric, g=guid, b=opaque)
|
|
## identifier - OPC UA ID (tag as shown in opcua browser)
|
|
## tags - extra tags to be added to the output metric (optional)
|
|
## Example:
|
|
## {name="ProductUri", namespace="0", identifier_type="i", identifier="2262", tags=[["tag1","value1"],["tag2","value2]]}
|
|
# nodes = [
|
|
# {name="", namespace="", identifier_type="", identifier=""},
|
|
# {name="", namespace="", identifier_type="", identifier=""},
|
|
#]
|
|
#
|
|
## Node Group
|
|
## Sets defaults for OPC UA namespace and ID type so they aren't required in
|
|
## every node. A group can also have a metric name that overrides the main
|
|
## plugin metric name.
|
|
##
|
|
## Multiple node groups are allowed
|
|
#[[inputs.opcua.group]]
|
|
## Group Metric name. Overrides the top level name. If unset, the
|
|
## top level name is used.
|
|
# name =
|
|
#
|
|
## Group default namespace. If a node in the group doesn't set its
|
|
## namespace, this is used.
|
|
# namespace =
|
|
#
|
|
## Group default identifier type. If a node in the group doesn't set its
|
|
## namespace, this is used.
|
|
# identifier_type =
|
|
#
|
|
## Node ID Configuration. Array of nodes with the same settings as above.
|
|
# nodes = [
|
|
# {name="", namespace="", identifier_type="", identifier=""},
|
|
# {name="", namespace="", identifier_type="", identifier=""},
|
|
#]
|
|
|
|
## Enable workarounds required by some devices to work correctly
|
|
# [inputs.opcua.workarounds]
|
|
## Set additional valid status codes, StatusOK (0x0) is always considered valid
|
|
# additional_valid_status_codes = ["0xC0"]
|