# Scale values with a predefined range to a different output range.
[[processors.scale]]
## It is possible to define multiple different scaling that can be applied
## do different sets of fields. Each scaling expects the following
## arguments:
## - input_minimum: Minimum expected input value
## - input_maximum: Maximum expected input value
## - output_minimum: Minimum desired output value
## - output_maximum: Maximum desired output value
## - fields: a list of field names (or filters) to apply this scaling to
## Example: Define a scaling
# [processors.scale.scaling]
# input_minimum = 0
# input_maximum = 1
# output_minimum = 0
# output_maximum = 100
# fields = ["temperature1", "temperature2"]
## Multiple scalings can be defined simultaneously
## Example: A second scaling.
# [processors.scale.scaling]
# input_minimum = 0
# input_maximum = 50
# output_minimum = 50
# output_maximum = 100
# fields = ["humidity*"]